Centralized Heat Pump
Racold Heat Pump
Racold heat pumps are efficient water heating solutions offering up to 70% electricity savings, available in 150L, 200L, 300L, and 500L capacities for residential/commercial use.
Key Specifications (150L - 300L Series):
Key Specifications (150L - 300L Series):
- Capacities: 150, 200, 300, and 500 liters.
- Heating Method: Air-to-water heat pump with electric backup.
- Operating Pressure: 8 Bar.
- Electrical Input: 220V-240V, 50Hz single-phase.
- Power Input (Heat Pump): ~620W - 720W.
- Backup Heater: 1.5 kW to 2.0 kW.
- Max Water Temp (HP Mode): 55°C (up to 62°C in some models).
- Max Water Temp (Element Mode): 75°C.
- Refrigerant: R134a.
- Noise Level: ~52 dB(A).
- Installation: Floor-mounted, available as split or monobloc.

Key Features :
Titanium Plus Enamel Tank: Protects against rust and hard water.- Intelligent Controller: Allows scheduling and temperature settings.
- Isolated Safe Condenser: European standard for safety and efficiency.
- Warranty: Typically includes 4-7 years on the tank and 1-2 years on electrical components.

Features :
- Storage tank Volume 200 L and 300 L
- Versions with Integrated smooth-pipe heat exchanger
- Operation temperature range from +7 degree C to +40 degree C
- Heating of water with Heat pump up to 65 degree C
- Maximum temperature of Domestic Water 75 degree C
- COP (A20 / W10 - 55 ) EN 16147: 4.4
- Tank is made of a high quality steel sheet metal, enamelled at 850 degree C
- Magnesium anode for additional protection of the tank from corrosion
- Built in electric heater 2 KW as an additional or spare source of water heating
- Shell and tube condenser
- Eco friendly refrigerant R134a.
- Electronic Control unit with mechanical buttons and LED indicator enables :
- Setting water temperature ranging from 10 degree C to 75 degree C
- Display of water temperature in the tank
- Quick heating to the desired temperature ( simultaneous heating of water with the heat pump
and electrical heater )
- Heating to a higher temperature of 75 degree C , Heat pump up to 65 degree C, Electric heater from
65 degree C to 75 degree C
- Automatic anti legionella programme with disinfection ( 70 degree C ) - Possible to Switch Off
- Indication of functioning in the reverse mode.